Underground mine refuge alternatives heat mitigation
Yan L , Yantek D , Lutz T , Yonkey J , Srednicki J . J Therm Sci Eng Appl 2020 12 (2) 021019 In case of an emergency in an underground coal mine, miners who fail to escape from the mine can enter a refuge alternative (RA) for protection from adverse conditions, such as high carbon monoxide levels. One of the main concerns with the use of both portable and built-in-place (BIP) RAs, especially for hot or deep mines, is the interior temperature rise due to the occupants' metabolic heat and the heat released by devices such as the carbon dioxide (CO2) scrubbing system. The humidity within the RA will also increase through occupants' respiration and perspiration and from the chemical reaction within the CO2 scrubbing system. Heat and humidity buildup can subject the occupants to hazardous thermal conditions. To protect RA occupants, Mine Safety and Health Administration regulations mandate a maximum apparent temperature of 95F within an occupied RA. The National Institute for Occupational Safety and Health (NIOSH) tested both an air-conditioned borehole air supply (BAS) and a cryogenic air supply for RAs in the NIOSH Experimental Mine in Bruceton, Pennsylvania. The BAS was tested on a 60-person BIP RA, while the cryogenic air supply was tested on a 30-person BIP RA and a portable 23-person tent-type RA. Multiple tests were conducted with both air supplies to assess their ability to cool RAs. The test results show that the BAS and the cryogenic air supply were able to maintain the apparent temperature within the tested RAs under the 95F limit. The BAS and the cryogenic air supply are potential RA heat mitigation strategies that mines could use to prevent heat/humidity buildup within RAs. |
Refuge alternatives relief valve testing and design with updated test stand
Lutz TJ , Bissert PT , Homce GT , Yonkey JA . Min Eng 2018 70 (3) 46-50 Underground refuge alternatives require an air source to supply breathable air to the occupants. This requires pressure relief valves to prevent unsafe pressures from building up within the refuge alternative. The U.S. Mine Safety and Health Administration (MSHA) mandates that pressure relief valves prevent pressure from exceeding 1.25 kPa (0.18 psi), or as specified by the manufacturer, above mine atmospheric pressure when a fan or compressor is used for the air supply. The U.S. National Institute for Occupational Safety and Health (NIOSH) tested a variety of pressure relief valves using an instrumented test fixture consisting of data acquisition equipment, a centrifugal blower, ductwork and various sensors to determine if the subject pressure relief valves meet the MSHA requirement. Relief pressures and flow characteristics, including opening pressure and flow rate, were measured for five different pressure relief valves under a variety of conditions. The subject pressure relief valves included two off-the-shelf modified check valves, two check valves used in MSHA-approved built-in-place refuge alternatives, and a commercially available valve that was designed for a steel refuge alternative and is currently being used in some built-in-place refuge alternatives. The test results showed relief pressures ranging from 0.20 to 1.53 kPa (0.03 to 0.22 psi) and flow rates up to 19.3 m3/min (683 scfm). As tested, some of the pressure relief valves did not meet the 1.25 kPa (0.18 psi) relief specification. |
Refuge alternatives relief valve testing and design
Lutz TJ , Bissert PT , Homce GT , Yonkey JA . Min Eng 2016 68 (10) 55-59 The U.S. National Institute for Occupational Safety and Health (NIOSH) has been researching refuge alternatives (RAs) since 2007. RAs typically have built-in pressure relief valves (PRVs) to prevent the unit from reaching unsafe pressures. The U.S. Mine Safety and Health Administration requires that these valves vent the chamber at a maximum pressure of 1.25 kPa (0.18 psi, 5.0 in. H2O), or as specified by the manufacturer, above mine atmospheric pressure in the RA. To facilitate PRV testing, an instrumented benchtop test fixture was developed using an off-the-shelf centrifugal blower and ductwork. Relief pressures and flow characteristics were measured for three units: (1) a modified polyvinyl chloride check valve, (2) an off-the-shelf brass/cast-iron butterfly check valve and (3) a commercially available valve that was designed specifically for one manufacturer's steel prefabricated RAs and had been adapted for use in one mine operator's built-in-place RA. PRVs used in tent-style RAs were not investigated. The units were tested with different modifications and configurations in order to check compliance with Title 30 Code of Federal Regulations, or 30 CFR, regulations. The commercially available relief valve did not meet the 30 CFR relief pressure specification but may meet the manufacturer's specification. Alternative valve designs were modified to meet the 30 CFR relief pressure specification, but all valve designs will need further design research to examine survivability in the event of a 103 kPa (15.0 psi) impulse overpressure during a disaster. |
- Page last reviewed:Feb 1, 2024
- Page last updated:May 06, 2024
- Content source:
- Powered by CDC PHGKB Infrastructure